JHMI

Joist Hanger for Masonry: I-Joists

The JHM and JHMI range of joist hangers can be used to connect solid sawn
joists, trusses and engineered joists to masonry walls or steel beams.

CE Marking

Product Details

Features

Material

  • Pre-galvanised mild steel

Benefits

  • Built-in inspection slot at the base of the hanger to aid inspection
    from the ground.
  • Top flange provides widest area in contact with masonry support allowing superior performance.
  • Embossments on top flange, and holes, allow improved mortar keying.
  • Flanges on hangers are much higher than traditional style, providing greatly enhanced resistance to joist rotation.
  • Can be installed onto ‘I’ section or hollow section steel beams.

Mechanically Fixing to Steel

Application

Options

  • Return configuration provides additional support by wrapping around three sides of the block. Designate "return" and length of return dimensions when ordering.
  • JHMI, JHMIR OR JHMIS HANGERS DO NOT SATISFY THE REQUIREMENTS FOR LATERAL RESTRAINT TYPE HANGERS UNLESS STRAPS ARE FITTED.
  • Straddle configuration provides two hangers connected across top of support enabling exact alignment on both sides of supporting wall. Designate "straddle" and length of straddle dimensions when ordering.
  • Other widths and heights available to order.

Technical Data

Dimensions

Product Dimensions

References Joist dimensions [mm] Hanger Dimensions [mm] Joist holes
Width Height A B C D E F t Ø4
JHMI195/4038195401956464757522
JHMI200/4038200402006464757522
JHMI220/4038220402206464757522
JHMI225/4038220402256464757522
JHMI235/4038235402356464757522
JHMI240/4038240402406464757522
JHMI245/4038245402456464757522
JHMI300/4038300403006464757522
JHMI360/4038360403606464757522
JHMI400/4038400404006464757522
JHMI145/4745145471456464757522
JHMI195/4745195471956464757522
JHMI200/4745200472006464757522
JHMI220/4745220472206464757522
JHMI225/4745220472256464757522
JHMI235/4745235472356464757522
JHMI240/4745240472406464757522
JHMI245/4745245472456464757522
JHMI300/4745300473006464757522
JHMI350/4745350473506464757522
JHMI360/4745360473606464757522
JHMI400/4745400474006464757522
JHMI220/5047220502206464757522
JHMI225/5047220502256464757522
JHMI240/5047240502406464757522
JHMI300/5047300503006464757522
JHMI220/5653220562206464757522
JHMI225/5653220562256464757522
JHMI240/5653240562406464757522
JHMI300/5653300563006464757522
JHMI200/6158200612006464757522
JHMI360/6158360613606464757522
JHMI400/6158400614006464757522
JHMI200/6360200632006464757522
JHMI220/6360220632206464757522
JHMI225/6360220632256464757522
JHMI240/6360240632406464757522
JHMI300/6360300633006464757522
JHMI350/6360350633506464757522
JHMI360/6360360633606464757522
JHMI400/6360400634006464757522
JHMI220/6663220662206464757522
JHMI225/6663220662256464757522
JHMI235/6663235662356464757522
JHMI240/6663240662406464757522
JHMI245/6663245662456464757522
JHMI300/6663300663006464757522
JHMI200/7270200722006464757522
JHMI220/7270220722206464757522
JHMI225/7270220722256464757522
JHMI240/7270240722406464757522
JHMI300/7270300723006464757522
JHMI360/7270360723606464757522
JHMI400/7270400724006464757522
JHMI195/7572195751956464757522
JHMI200/7572200752006464757522
JHMI220/7572220752206464757522
JHMI225/7572220752256464757522
JHMI235/7572235752356464757522
JHMI240/7572240752406464757522
JHMI245/7572245752456464757522
JHMI253/7572253752536464757522
JHMI300/7572300753006464757522
JHMI304/7572304753046464757522
JHMI350/7572350753506464757522
JHMI360/7572360753606464757522
JHMI400/7572400754006464757522
JHMI417/7572417754176464757522
JHMI421/7572421754216464757522
JHMI195/782x38195781956464757522
JHMI200/782x38200782006464757522
JHMI220/782x38220782206464757522
JHMI225/782x38220782256464757522
JHMI235/782x38235782356464757522
JHMI240/782x38240782406464757522
JHMI245/782x38245782456464757522
JHMI300/782x38300783006464757522
JHMI360/782x38360783606464757522
JHMI400/782x38400784006464757522
JHMI195/912x45 or 89-90195911956464757522
JHMI200/912x45 or 89-90200912006464757522
JHMI220/912x45 or 89-90220912206464757522
JHMI225/912x45 or 89-90220912256464757522
JHMI235/912x45 or 89-90235912356464757522
JHMI240/912x45 or 89-90240912406464757522
JHMI245/912x45 or 89-90245912456464757522
JHMI253/912x45 or 89-90253912536464757522
JHMI300/912x45 or 89-90300913006464757522
JHMI350/912x45 or 89-90350913506464757522
JHMI360/912x45 or 89-90360913606464757522
JHMI400/912x45 or 89-90400914006464757522
JHMI220/962x47220962206464757522
JHMI225/962x47220962256464757522
JHMI240/962x47240962406464757522
JHMI300/962x47300963006464757522
JHMI195/9996-97195991956464757522
JHMI200/9996-97200992006464757522
JHMI220/9996-97220992206464757522
JHMI225/9996-97220992256464757522
JHMI235/9996-97235992356464757522
JHMI240/9996-97240992406464757522
JHMI245/9996-97245992456464757522
JHMI253/9996-97253992536464757522
JHMI300/9996-97300993006464757522
JHMI304/9996-97304993046464757522
JHMI350/9996-97350993506464757522
JHMI360/9996-97360993606464757522
JHMI373/9996-97373993736464757522
JHMI400/9996-97400994006464757522
JHMI417/9996-97417994176464757522
JHMI421/9996-97421994216464757522
JHMI220/1092x532201092206464757522
JHMI225/1092x532201092256464757522
JHMI240/1092x532401092406464757522
JHMI300/1092x533001093006464757522
JHMI200/1222x602001222006464757522
JHMI220/1222x602201222206464757522
JHMI225/1222x602201222256464757522
JHMI240/1222x602401222406464757522
JHMI300/1222x603001223006464757522
JHMI350/1222x603501223506464757522
JHMI360/1222x603601223606464757522
JHMI400/1222x604001224006464757522
JHMI195/1251251951251956464757522
JHMI200/1251252001252006464757522
JHMI220/1251252201252206464757522
JHMI225/1251252251252256464757522
JHMI253/1251252531252536464757522
JHMI304/1251253041253046464757522
JHMI373/1251253731253736464757522
JHMI417/1251254171254176464757522
JHMI421/1251254211254216464757522
JHMI220/1282x632201282206464757522
JHMI225/1282x632201282256464757522
JHMI235/1282x632351282356464757522
JHMI240/1282x632401282406464757522
JHMI245/1282x632451282456464757522
JHMI300/1282x633001283006464757522
JHMI200/1422x70 or 1402001422006464757522
JHMI220/1422x70 or 1402201422206464757522
JHMI225/1422x70 or 1402201422256464757522
JHMI240/1422x70 or 1402401422406464757522
JHMI300/1422x70 or 1403001423006464757522
JHMI360/1422x70 or 1403601423606464757522
JHMI400/1422x70 or 1404001424006464757522
JHMI195/1462x721951461956464757522
JHMI200/1462x732001462006464757522
JHMI220/1462x742201462206464757522
JHMI225/1462x752251462256464757522
JHMI235/1462x762351462356464757522
JHMI240/1462x772401462356464757522
JHMI245/1462x782451462456464757522
JHMI300/1462x803001463006464757522
JHMI350/1462x823501463506464757522
JHMI360/1462x843601463606464757522
JHMI400/1462x864001464006464757522
JHMI195/1502x75 or 1471951501956464757522
JHMI200/1502x75 or 1472001501956464757522
JHMI220/1502x75 or 1472201502206464757522
JHMI225/1502x75 or 1472251502256464757522
JHMI235/1502x75 or 1472351502356464757522
JHMI240/1502x75 or 1472401502406464757522
JHMI245/1502x75 or 1472451502456464757522
JHMI253/1502x75 or 1472531502536464757522
JHMI300/1502x75 or 1473001503006464757522
JHMI304/1502x75 or 1473041503046464757522
JHMI360/1502x75 or 1473601503606464757522
JHMI373/1502x75 or 1473731503736464757522
JHMI400/1502x75 or 1474001504006464757522
JHMI417/1502x75 or 1474171504176464757522
JHMI421/1502x75 or 1474211504216464757522

Product Capacities - Masonry

References Joist Fasteners Characteristic Capacity [kN] Safe Working Loads
Qty Type R1,k R2,k R1,SWL R2,SWL,Short Term
2.8N/mm² Solid AAC 3.5N/mm² Solid LAC 7.0N/mm² Solid DAC 2.8N/mm² Solid AAC 3.5N/mm² Solid LAC 7.0N/mm² Solid DAC
JHMI23.75 x 3010.512.8201.85.26.4101

Product Capacities - Masonry & Skewed

References Joist Fasteners Safe Working Loads
Qty Type R1,SWL R2,SWL,Short Term
2.8N/mm² Solid AAC 3.5N/mm² Solid LAC 7.0N/mm² Solid DAC
SPEC JHMSK4N3.75x3055.15.1-

1. Maximum skew 45º

Product Capacities - Shot Fired to Steel Girder

References Number of Fasteners Safe Working Loads
Header Joist R1,SWL,Long Term
Qty Type Qty Type
JHMI4Shot Fire Pns*2N3.75x305.1

1.The above Safe Working Loads are based upon product tests using four No. Hilti 12mm X-EDNI steel pins fired through holes provided in the top flange of the hangers onto 4mm thick steel plate. Other pins may be used provided similar structural performance is verified by the pin manufacturer. Pin Head size must be sufficient to prevent pull through during loading.
2.The designer must ensure that the steel support member will support the imposed loads.
3.Install shot-fired pins in accordance with manufacturer’s instructions.

Product Performance - Mechanically Fixed to Steel Beam

References Number of Fasteners Safe Working Loads [kN] Characteristic Load [kN]
Header Joist R1, SWL, Long Term R1,k
Qty Type Qty Type
JHMI2XLQ114B12242N3.75x3010.819
  • The designer / engineer must ensure that the steel support can take the imposed loads
  • Suitable for Steel I-beams and Hollow Sections upto 12.5mm thick
  • Timber is required in the web of steel I-beam when the hanger depth is less than the steel depth.  Timber must finish flush with outer edges of steel I-beam
Fastener Reference

Length

[mm]

Hex Head

[in]

Washer Diameter

[mm]

Shank Diameter

[mm]

Suitable Material Thickness

[mm]

Recommended Install Speed

[RPM]

XLQ114B1224325/16"165.53.5 - 12.51400


 

Installation

Installation

Ínstallation

Standard Masonry Installation

  • Use all specified fasteners. See table.
  • Hanger must be installed so that the back flange is tight against the face of the supporting member.
  • MINIMUM 3 COURSES OF SOLID BLOCK (675MM MASONRY)
    REQUIRED ABOVE HANGER, WITH MORTAR FULLY CURED,
    BEFORE APPLYING LOAD.
  • Do not stack blocks or heavy loads on the joists during construction unless the joists have additional support to take the full load of the blocks, vertically and horizontally.

Fixed to Steel Beams

  • The JHMI range can be mechanically fixed to steel beams of
    thicknesses up to 12.5mm
  • Timber is required in the web of the ‘I’ section steel beam when
    the hanger depth is less than the steel depth
  • Timber must be flush with the outer edges of the ‘I’ section steel
    beam
  • The shot-fired pins must be installed by a qualified person in accordance with the manufacturer’s installation requirements.

Certification

Declaration of Performance (DoP)

CAD and BIM Library

2D
3D
3D Simplified

ZIP Packages

Buy from Distributor

No items available.

Contact

Simpson Strong-Tie U.K.

Simpson Strong-Tie

Cardinal Point, Winchester Road
Tamworth
Staffordshire
B78 3HG
United Kingdom